15KW high frequency igbt driver board magnetic induction heater control kit and parts for industrial heating
¥719.00

Discount
[new_user_coupon_discount_and_code]
15KW High Frequency IGBT Driver Board Magnetic Induction Heater Control Kit And Parts for Industrial heating
Technical Parameters
|
Item |
Technical Parameters |
|
Rated power |
15KW Three-phase 380V |
|
Rated input current |
15KW (20-22A) |
|
Rated output current |
15KW (60-70A) |
|
Rated voltage frequency |
AC 380V/50Hz |
|
Voltage adaptation range |
constant power output at 300 ~ 400V |
|
Adapt to ambient temperature |
-20?C~50?C |
|
Adapt to environmental humidity |
¡Ü95% |
|
Power adjustment range |
20% ~ 100% stepless adjustment(That is: adjustment between 0.5 ~ 15KW) |
|
Heat conversion efficiency |
¡Ý95% |
|
Effective power |
¡Ý98%(Can be customized according to user needs) |
|
working frequency |
5~40KHz |
|
Main circuit structure |
Half-bridge series resonance |
|
Control System |
DSP-based high-speed automatic phase-locking tracking control system |
|
Application mode |
Open application platform |
|
monitor |
Programmable digital display |
|
start time |
<1S |
|
Instantaneous overcurrent protection time |
¡Ü2US |
|
Power overload protection |
130% instantaneous protection |
|
Soft start mode |
Fully electrically isolated soft start heating / stop mode |
|
Support PID adjustment power |
Identify 0-5V input voltage |
|
Support 0 ~ 150 ?C load temperature detection |
Accuracy up to ¡À 1 ?C |
|
Adaptive coil parameters |
15KW 16 square line, length 25~30m, inductance 110 ~ 140uH |
|
Coil to load distance(Thermal insulation thickness) |
20-25mm for circle, 15-20mm for plane, 10-15mm for ellipse and within 10 mm for super ellipse |
Winding Method Of Coil:
figure. Wrap the 15-20mm thick insulation cotton before winding, and
leave the 10-20cm interval for each section and then go around the next
section. The temperature probe of the thermostat can be fixed in the
interval. When a plurality of induction heaters are connected in
parallel, the coil spacing must be 20cm or more. If thicker insulation
is needed, please consult our company’s technical personnel.








Contact US